RNA slot-blot

A. Kumar akumar at blue.weeg.uiowa.edu
Wed Jan 29 18:13:11 EST 1997


Is the slot-methods reliable for quantitative RNA analysis ? We used a
slot blot with different amounts of the same RNA and probed it with a cDNA
probe. The signal as measured by densitometry was proportional to the
amount of RNA but the slope was not 1. I am concerned of the reliability
of this method Vs conventional Northern blot analysis. The protocol
followed was as mentioned in "Current Protocols" (the red book). If there
is a better protocol, I'd appreciate any input.
Thanks.
Ashish Kumar


 
		   WORKPLACE			DEN
		
		Dept. of Anatomy,           735 Michael St. Apt 34
		College of Medicine,	    Iowa City
		University of Iowa,	    IA 52246-5523
		Iowa City, IA 52242

		Dial (319)335-7739           (319)338-0529

		e : ashish-kumar at uiowa.edu


	